{"product_id":"sanwa-em7000-analog-multimeter-high-sensitivity-fet-for-measurement-of-lower-capacitance","title":"Sanwa EM7000 Analog Multimeter - High Sensitivity FET for Measurement of Lower Capacitance","description":"\u003cp\u003e\u003cstrong\u003eHIGHLIGHTS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Sanwa EM7000 is a highly sensitive FET electronic analog multimeter.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003eThe EM7000 is a FET (field-effect transistor) analog multimeter with a zero-deflection scale\u003c\/strong\u003e, which is great for testing low-power circuits. It has an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eaccuracy of ±3.0%\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof full scale, and can also measure the peak-to-peak values of an input signal (triangular, square-wave) over a 20% duty cycle. The device is also capable of measuring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eresistances up to 200MΩ\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehighly sensitive when measuring lower value capacitances.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt is recommended to use the device in an environment with a temperature less than 40 degrees Celsius at a maximum altitude of 2000m indoor, with pollution degrees level II. \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe EM7000 comes with a set of test leads (TL-21a), instruction manual and a spare fuse (250V \/ 0.5A). The device is professionally calibrated by Sanwa and comes with a certificate of calibration.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eZero center meter (NULL) of DC Voltage and DC Current\u003c\/li\u003e\n\u003cli\u003eThe frequency characteristic of AC low voltage ranges(3V and 12V) is 40Hz～1MHz (sine wave AC)\u003c\/li\u003e\n\u003cli\u003eThe Vp-p of triangular-wave, square-wave over 20% duty cycle voltages of waveforms can also be measured (at 3V range)\u003c\/li\u003e\n\u003cli\u003eWide ohm range 0.2Ω～200MΩ\u003c\/li\u003e\n\u003cli\u003e±3.0% of full scale\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cstyle\u003e\ntable {\n  border: none;\n  border-collapse: collapse;\n  width: 100%;\n  }\n\ntd {\n  border: none;\n  text-align: left;\n padding: 3px;\n   color:black;\n}\n  td:first-child {\n    font-weight: bold;\n  }\nth {\n  text-align: left;\n}\n\ntr:nth-child(odd) {\n  background-color: #E6EEF0;\n}\n--\u003e\u003c\/style\u003e\n\u003ctable\u003e\n\u003ccaption\u003e\u003cspan style=\"color: #0b5394; float: left;\"\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/caption\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable cellpadding=\"6\" cellspacing=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eTolerance\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDCV\u003c\/td\u003e\n\u003ctd\u003e0.3\/1.2\/3\/12\/30\/120\/300\/1000V (2.5~12MΩ)\u003c\/td\u003e\n\u003ctd\u003e±3% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e±DCV\u003c\/td\u003e\n\u003ctd\u003e±0.15\/0.6\/1.5\/6\/15\/60\/150\/600V (2.5~12MΩ)\u003c\/td\u003e\n\u003ctd\u003e±7% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC voltage rms (50\/60Hz)\u003c\/td\u003e\n\u003ctd\u003e3V (approx.2.5MΩ) \/ 12V (approx.1.1MΩ) \/ 30V\/120\/300V (approx.800kΩ) \/ 750V (approx.10MΩ)\u003c\/td\u003e\n\u003ctd\u003e±3% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003eACV P-P\u003c\/td\u003e\n\u003ctd\u003eSine wave 8.4V (approx.2.5MΩ\/V) \/ 33V (approx.1MΩ) \/ 84\/330\/840V (approx.800kΩ)\u003c\/td\u003e\n\u003ctd\u003e±5% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSquare wave 8.4V (2.5MΩ)\u003c\/td\u003e\n\u003ctd\u003e±6% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTriangle wave 8.4V (2.5MΩ)\u003c\/td\u003e\n\u003ctd\u003e±6% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDCA\u003c\/td\u003e\n\u003ctd\u003e0.12µ\/0.3m\/3m\/30m\/300m\/6A\u003c\/td\u003e\n\u003ctd\u003e±3% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDCA\u003c\/td\u003e\n\u003ctd\u003e±0.6µ\/±0.15m\/1.5m\/15m\/150mA\u003c\/td\u003e\n\u003ctd\u003e±7% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACA\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003ctd\u003e±5% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance\u003c\/td\u003e\n\u003ctd\u003e2k\/20k\/200k\/2M\/20M\/200MΩ\u003c\/td\u003e\n\u003ctd\u003e±3% of arc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow-frequency output\u003c\/td\u003e\n\u003ctd\u003e-10 ~ 51dB\u003c\/td\u003e\n\u003ctd\u003e±3% of arc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ctable cellpadding=\"6\" cellspacing=\"0\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency characteristic\u003c\/td\u003e\n\u003ctd\u003eAC12V range or lower 40Hz to 1 MHz: frequency response within ±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eR6P(AA battery)1.5V×2, 6F22(9V manganese battery)×1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in fuse\u003c\/td\u003e\n\u003ctd\u003eF1176 Φ5×20mm 0.5A\/250V 1.5kA Ceramic fuse\u003cbr\u003eF1177 Φ5×20mm 6.3A\/250V 1.5kA Ceramic fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\/Mass\u003c\/td\u003e\n\u003ctd\u003eH165×W106×D46mm \/ Approx. 375g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003ci\u003e*The value in ( ) at DCV and ACV is input resistance\u003c\/i\u003e\u003c\/p\u003e","brand":"Sanwa","offers":[{"title":"Default Title","offer_id":47680990544104,"sku":null,"price":10200.0,"currency_code":"PHP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0728\/1777\/files\/EM7000.jpg?v=1757987561","url":"https:\/\/www.gigatools.live\/products\/sanwa-em7000-analog-multimeter-high-sensitivity-fet-for-measurement-of-lower-capacitance","provider":"GIGATOOLS Industrial Center","version":"1.0","type":"link"}